해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-

폐지
판매
CSA C22.2 NO. 250.570:16 (R2020)
Track lighting- 발행일 : 2016-01-01
- 발행기관 : CSA
상세정보
| 분야 | 11 : LG Electronics |
|---|---|
| 적용범위 | Preface This is the first edition of CSA C22.2 No. 250.570, Track lighting, one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard contains specific requirements for track lighting and is intended to be used together with the requirements for luminaires contained in CSA C22.2 No. 250.0. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0. ? Scope 1.1 This Standard applies to wall and ceiling-mounted track lighting systems, rated 347 V, 40 A max, incorporating incandescent, fluorescent, light emitting diodes and high-intensity discharge lighting sources, intended to be installed in non-hazardous, dry locations in accordance with the Canadian Electrical Code, Part I. 1.2 This Standard applies to plug- and cord-connected track lighting systems rated 120 V. 1.3 This Standard applies to permanently connected incandescent or LED lighting systems supported in free air, employing bare conductors. The power supply for supplying luminaire head assemblies may have one or more secondary output circuits each of which operates at up to 30 V rms or 42.4 V peak or dc, and less than 240 V?A. 1.4 This Standard applies also to extra-low-voltage suspended ceiling grid systems that operate at 30 V rms or 42.4 V peak, or less, connected to Class 2 power supplies. 1.5 This Standard is intended to be used in conjunction with the applicable clauses of CSA C22.2 No. 250.0 and its subsequent revisions. 1.6 Lighting tracks shall not be connected to a branch circuit protected by overcurrent devices rated or set at more than a) 15 A in dwelling units; b) 20 A in other than dwelling units, where the input voltage does not exceed 347 V nominal; or c) 40 A in other than dwelling units, where the load is from i) luminaires with lampholders of the incandescent mogul base type; ii) high-intensity discharge (HID) luminaires, with or without auxiliary lighting systems, where the input voltage does not exceed 120 V nominal; iii) tungsten halogen luminaires with double-ended lampholders, where the input voltage does not exceed 240 V nominal; or iv) luminaires provided with an integral overcurrent device rated at not more than 15 A, where the input voltage does not exceed 120 V nominal. 1.7 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.8 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. |
| 국제분류(ICS)코드 | |
| 페이지수 | 58 |
| Edition |
이력정보
| No. | 표준번호 | 표준명 | 발행일 | 상태 |
|---|---|---|---|---|
| 1 | CSA C22.2 NO. 250.570:24상세보기 | Track lighting | 2024-01-01 | 표준 |
| 2 | CSA C22.2 NO. 250.570:16 (R2020)상세보기 | Track lighting | 2016-01-01 | 폐지 |
관련상품
- 관련상품이 존재하지 않습니다.
다른 사람이 함께 구입한 상품
- CSA C866:17 (R2022) - Performance of LED luminaires
- CSA C22.2 NO. 43:17 (R2022) - Lampholders (Binational standard with UL 496)
- CSA C22.2 NO. 250.0:21 - Luminaires (Trinational standard with UL 1598 and NMX-J-307/1-ANCE)
- CSA E60598-2-1:23 - Luminaires — Part 2-1: Particular requirements — Fixed general purpose luminaires (Adopted IEC 60598-2-1:2020, second edition, 2020-01, with Canadian deviations) | Luminaires — Partie 2-1 : Exigences particulières — Luminaires fixes à usage général (norme
- B366.1-11 (R2020) - Solid-fuel-fired central heating appliances
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO/TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO/TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)보안PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능ASME PBVC Plus :
인쇄본 우편발송 및 온라인 구독(1User용, 2년)